FREE FREIGHT - Online Orders over $50 - Limited Time Only

{"id":4284095233,"title":"(2180) ADAMS ACID INJECTOR 5-8 GPM 2.3mm QC KIT","handle":"adams-acid-injector-5-8-gpm-2-3mm-qc-kit","description":"Downstream injectors are installed after the pump. In order to function, the pressure must be lowered with the use of either a dual lance and soap nozzle, a variable nozzle, a dual nozzle holder, or an adjustable nozzle holder. Water enters the inlet of the injector and creates a venturi which drops the pressure and suctions the chemical from container. Chemical can be injected either in concentrated form or in diluted form. Chemical can be regulated by turning the dial on the injector or installing a metering device on the chemical line. The injector contains a check valve to prevent water from flowing into the chemical container while in high pressure mode.\n\u003cp\u003e\u003cstrong\u003eNOTE: Length of hose will determine ability of injector to work properly. It is recommended to keep hose length at 100 feet or less.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDraw rate 0 to 20%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cli\u003e\u003cstrong\u003eCeramic ball for injecting acids\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating pressure: 3000 PSI.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum 35% pressure drop for draw.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum Temperature: 194 degrees F.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInlet: 3\/8\" MPT.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutlet: 3\/8\" MPT.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2016-02-24T10:47:00-05:00","created_at":"2016-02-24T10:47:05-05:00","vendor":"JE Adams","type":"Injectors","tags":["acid injector","chemical injector"],"price":4075,"price_min":4075,"price_max":4075,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12273608065,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2180","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"(2180) ADAMS ACID INJECTOR 5-8 GPM 2.3mm QC KIT","public_title":null,"options":["Default Title"],"price":4075,"weight":454,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1183\/1612\/products\/1958__35007.1383897564.120.120.jpg?v=1479773320"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1183\/1612\/products\/1958__35007.1383897564.120.120.jpg?v=1479773320","options":["Title"],"content":"Downstream injectors are installed after the pump. In order to function, the pressure must be lowered with the use of either a dual lance and soap nozzle, a variable nozzle, a dual nozzle holder, or an adjustable nozzle holder. Water enters the inlet of the injector and creates a venturi which drops the pressure and suctions the chemical from container. Chemical can be injected either in concentrated form or in diluted form. Chemical can be regulated by turning the dial on the injector or installing a metering device on the chemical line. The injector contains a check valve to prevent water from flowing into the chemical container while in high pressure mode.\n\u003cp\u003e\u003cstrong\u003eNOTE: Length of hose will determine ability of injector to work properly. It is recommended to keep hose length at 100 feet or less.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDraw rate 0 to 20%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cli\u003e\u003cstrong\u003eCeramic ball for injecting acids\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating pressure: 3000 PSI.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum 35% pressure drop for draw.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum Temperature: 194 degrees F.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInlet: 3\/8\" MPT.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutlet: 3\/8\" MPT.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cp\u003e \u003c\/p\u003e"}

(2180) ADAMS ACID INJECTOR 5-8 GPM 2.3mm QC KIT

Product Description
Downstream injectors are installed after the pump. In order to function, the pressure must be lowered with the use of either a dual lance and soap nozzle, a variable nozzle, a dual nozzle holder, or an adjustable nozzle holder. Water enters the inlet of the injector and creates a venturi which drops the pressure and suctions the chemical from container. Chemical can be injected either in concentrated form or in diluted form. Chemical can be regulated by turning the dial on the injector or installing a metering device on the chemical line. The injector contains a check valve to prevent water from flowing into the chemical container while in high pressure mode.

NOTE: Length of hose will determine ability of injector to work properly. It is recommended to keep hose length at 100 feet or less.

Draw rate 0 to 20%

  • Ceramic ball for injecting acids
  • Operating pressure: 3000 PSI.
  • Minimum 35% pressure drop for draw.
  • Maximum Temperature: 194 degrees F.
  • Inlet: 3/8" MPT.
  • Outlet: 3/8" MPT.
  •  